When using the Relisys TR-170 terminal for operation with CCI
Concurrent DOS or Multiuser DOS, the following settings
are recommended. To enter the SETUP mode on a Relisys TR-170,
press Shift and the gray numeric keypad minus (-) key. Options
which differ from the factory settings are marked with an
asterisk (*).
Note: Run the TERMSET command with the syntax "TERMSET ST n RELISYS"
(where n = station number) to define the port properly.
- F1 DISP
-
Column = 80 Attribute Mode = VGA
- Row = 25 Attribute Type = Blink
- Background = Normal Color Attribute = On
-
Overscan (mono) = Background Normal Foreground = White
- Fresh Rate = 70hz Normal Background = Black
- Cursor = Blink UL Reverse Foreground = Black
-
Screen Saver = 30min Reverse Background = White
- Status Line = Off
-
F2 GEN
- Personality = CCI Concurrent * Wrap = Off *
-
Margin Bell = Off Scroll = On
- Bell Volume = 8 * Rx CR = CR
- Monitor = Off Insert Mode = Off
- F3 KYBD
- Repeat Rate = 10 * Keyboard = US
- Keyclick = Off Language = Code Page 437
-
Key Code = PC Scan Break = Off
- Key Code TX Limit = 30 cps * Backspace = BS/DEL
-
F4 PNTR
- Printer Port = Serial * Formfeed = Off
-
Transparent = Off Line Terminator = CR *
- Printer = Off
-
F5 MAIN
- Baud Rate = 38.4K Stop Bit = 1
-
Data Bits = 8 Handshake = Both *
-
Parity = None *
- F6 AUX
-
Baud Rate = 9600 Stop Bit = 1
-
Data Bits = 8 Handshake = Both *
-
Parity = None * Receive = Off
|
|